HomeUncategorizedThe Importance of Existing Sense Resistor in Switch Mode Power Supply

The Importance of Existing Sense Resistor in Switch Mode Power Supply

Current feeling resistor is normally located in the switch mode power supply area. More recent variation of monitor-the b+ (increase) circuit also have this present feeling resistor. If you repair digital tools particularly the button setting Step Up Voltage Converter Module, the present picking up resistor is attached to the resource pin of power FET (area. Impact transistor) and the various other end to HOT GROUND. The worth of. current feeling resistor remains in the series of 0.1 ohm to concerning 1 ohm.

The worth is depending upon the layout of each power supply.

In screen Adjustable Dc Power Supply Module where pulse size modulation (pwm) ic UC3842. are made use of. Pin 3 of this power ic is called I-sense which means. current sense and this pin are linked to source pin of POWER FET. The function of this current feeling circuit is for overcurrent protection. This circuit normally examples the voltage decrease across a resistor in collection. With the changing fet transistor. If the existing increases extraordinarily due to. Some short circuit in the additional side such as a shorted additional diode. Straight output transistor (WARM), the voltage will certainly surpass a referral.

level and also closure the pulse generator which is the PWM ic. This circuit. provides protection to parts in the event an issue occurs. In some cases where overload happen-the power area will certainly blow and. Most of the moment the parts transformed are fuse, power fet, pwm ic,. Zener diode as well as present feeling resistor. Do you know that a little adjustment in this current sense resistor worth?

have a terrific effect on the secondary output? A little modification in value. Claim from 0.22 ohm to 0.44 ohm can created your outputs voltage to go down. Right into fifty percent. I have actually seen a great deal of repairer cannot detect this sort of. Problem (low outcome voltage) as a result of that they utilized analog or electronic. Meter that doesn’t have the reduced ohms vary. You can’t differentiate.

If the low ohms resistor has its worth altered by utilizing typical meters. I directly use the Cock Smith ESR Meter which have the capacities. Inspect resistor value down to 0.01 ohm! If you do not have this. Special meter you may simply route replace the current sense resistor. To see if the generated additional outcome will back to normal voltage.

An additional tip is that if the present sense resistor in the screen. B+ circuit have actually altered value it will certainly cause the outcome in the. Increase circuit to become low as well as you will certainly have a small size display screen. And also of course the high voltage will certainly end up being low also. Instead of. 24Kv it comes to be 15-18Kv.